Technical data

Key data at a glance!

The HV unit is perfectly tuned. The heat pump has a high coefficient of performance (COP).

Technical data   LI 8
Recommended for buildings with a heat output at -14°C outside temperature kW max. 8
HEAT PUMP    
Operating limit air temperature °C -20 to +35
Max. heat pump flow / min. return flow temperature °C 55/25
Air volume flow outside air/outgoing air m³/h 3000
Compression available externally outside air/outgoing air Pa 20
Heating water flow rate recommended/internal pressure loss (at dT 10K=approx. 0.1 better COP) m³/h / bar 1.3/0.10
Heating water flow rate max./internal pressure loss (at dT 5K) m³/h / bar 2.5/0.32
Nominal heat output/coefficient of performance A7/W35 kW/COP 10.40/5.20
Nominal heat output/coefficient of performance A7/W45 kW/COP 9.60/3.84
Nominal heat output/coefficient of performance A2/W35 kW/COP 8.90/4.45
Nominal heat output/coefficient of performance A2/W45 kW/COP 8.30/3.32
Nominal heat output/coefficient of performance A-7/W35 kW/COP 6.80/3.40
Nominal heat output/coefficient of performance A-7/W45 kW/COP 6.50/2.60
Power consumption scroll compressor A2/W35 kW 2.00
Refrigerant /filling quantity type/g R404a/2300
DIMENSIONS, CONNECTIONS, WEIGHT    
Dimensions H/W/D cm 139x65x75
Air connections heat pump outside air/outgoing air DN 600
Condenser-storage tank connections DN 1 1/4" IG
Condensate connection (hose) DN 3/4"
Weight approx. kg 210
ELECTRIC CONNECTION    
Rated power/protection kW/A 7.54/C16
Operating current scroll compressor A 8
Starting current scroll compressor A 40
Voltage/frequency V/Hz 400/50
Protection class according to EN 60529 IP 20
SOUND LEVEL LpA at 1 m distance with 100% HP    
Noise radiation housing dB(A) 53
Duct “to outdoor” without silencer dB(A) 72
MISCELLANEOUS    
Housing   steel sheet
Colour   white
Place of installation   inside
 